Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 13(9): e0204095, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30222755

RESUMO

PURPOSE: The aim of the study was to compare three different elastography methods, namely Strain Elastography (SE), Point Shear-Wave Elastography (pSWE) using Acoustic Radiation Force Impulse (ARFI)-Imaging and 2D-Shear Wave Elastography (2D-SWE), in the same study population for the differentiation of thyroid nodules. MATERIALS AND METHODS: All patients received a conventional ultrasound scan, SE and 2D-SWE, and all patients except for two received ARFI-Imaging. Cytology/histology of thyroid nodules was used as a reference method. SE measures the relative stiffness within the region of interest (ROI) using the surrounding tissue as reference tissue. ARFI mechanically excites the tissue at the ROI using acoustic pulses to generate localized tissue displacements. 2D-SWE measures tissue elasticity using the velocity of many shear waves as they propagate through the tissue. RESULTS: 84 nodules (73 benign and 11 malignant) in 62 patients were analyzed. Sensitivity, specificity and NPV of SE were 73%, 70% and 94%, respectively. Sensitivity, specificity and NPV of ARFI and 2D-SWE were 90%, 79%, 98% and 73%, 67%, 94% respectively, using a cut-off value of 1.98m/s for ARFI and 2.65m/s (21.07kPa) for 2D-SWE. The AUROC (Area under the Receiver Operating Characteristic) of SE, ARFI and 2D-SWE for the diagnosis of malignant thyroid nodules were 52%, 86% and 71%, respectively. A significant difference in AUROC was found between SE and ARFI (p = 0.008), while no significant difference was found between ARFI and SWE (86% vs. 71%, p = 0.31), or SWE and SE (71% vs. 52%, p = 0.26). CONCLUSION: pSWE using ARFI and 2D-SWE showed comparable results for the differentiation of thyroid nodules. ARFI was superior to elastography using SE.


Assuntos
Acústica , Diferenciação Celular , Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade , Ultrassonografia
2.
J Gastrointestin Liver Dis ; 26(3): 283-290, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28922441

RESUMO

BACKGROUND AND AIM: This is a prospective study for evaluation of 2D-shear wave elastography (2D-SWE) for characterisation and differentiation of benign und malignant focal liver lesions (FLLs). METHODS: The patients referred to our ultrasound unit were prospectively included. B-mode ultrasound and 2D-SWE (Aixplorer® France) were performed for one FLL in each patient. Liver histology and/or contrast-enhanced imaging were used as a reference method. RESULTS: 140 patients with FLL were included. SWE acquisitions failed in 24% of them. Therefore, 106 patients with FLL could be analysed, 42/106 with benign and 64/106 with malignant FLLs. The median stiffness for benign FLLs was 16.4 (2.1-71.9) kPa: 16.55 kPa for 18 focal nodular hyperplasia (FNH), 16.35 kPa for 18 hemangioma, 9.8 kPa for 3 focal fatty sparings (FFS), 8.9 kPa for 1 adenoma, 20 kPa for one regenerative node and 29 kPa for one cholangiofibroma, and for the malignant FLLs 36 (4.1-142.9) kPa: 44.8 kPa for 16 hepatocellular carcinoma (HCC), 70.7 kPa for 7 cholangiocarcinoma (CCC) and 29.5 kPa for the 41 metastasis (p<0.001). Malignant FLLs were significantly stiffer than benign FLLs (p<0.0001). Cholangiocarcinomas were the stiffest malignant FFLs with significantly higher values as compared to HCCs and metastases (p=0.033 and p=0.0079, respectively). No significant difference in stiffness could be observed between the different benign FLL entities. No significant difference was observed whether 2D-SWE included the whole FLL, the periphery or only the hardest area of the FLL. CONCLUSIONS: 2D-SWE provides further characterising information for interpretation of FLLs and may be useful at least in differentiation of CCCs and HCCs.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico por imagem , Carcinoma Hepatocelular/diagnóstico por imagem , Colangiocarcinoma/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Hiperplasia Nodular Focal do Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/patologia , Carcinoma Hepatocelular/patologia , Colangiocarcinoma/patologia , Meios de Contraste/administração & dosagem , Diagnóstico Diferencial , Feminino , Hiperplasia Nodular Focal do Fígado/patologia , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Adulto Jovem
3.
Anal Chem ; 87(7): 3806-11, 2015 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-25719361

RESUMO

In this paper, we report on the identification of batches of analgesic paracetamol (acetaminophen) tablets using nitrogen-14 nuclear quadrupole resonance spectroscopy ((14)N NQR). The high sensitivity of NQR to the electron charge distribution surrounding the quadrupolar nucleus enables the unique characterization of the crystal structure of the material. Two hypothesis were tested on batches of the same brand: the within the same batch variability and the difference between batches that varied in terms of their batch number and expiry date. The multivariate analysis of variance (MANOVA) did not provide any within-batches variations, indicating the natural deviation of a medicine manufactured under the same conditions. Alternatively, the statistical analysis revealed a significant discrimination between the different batches of paracetamol tablets. Therefore, the NQR signal is an indicator of factors that influence the physical and chemical integrity of the material. Those factors might be the aging of the medicine, the manufacturing, or storage conditions. The results of this study illustrate the potential of NQR as promising technique in applications such as detection and authentication of counterfeit medicines.


Assuntos
Acetaminofen/análise , Espectroscopia de Ressonância Magnética , Análise Multivariada , Nitrogênio/química , Comprimidos
4.
Anal Chem ; 85(5): 2746-53, 2013 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-23384229

RESUMO

We report the detection and analysis of a suspected counterfeit sample of the antimalarial medicine Metakelfin through developing nitrogen-14 nuclear quadrupole resonance ((14)N NQR) spectroscopy at a quantitative level. The sensitivity of quadrupolar parameters to the solid-state chemical environment of the molecule enables development of a technique capable of discrimination between the same pharmaceutical preparations made by different manufacturers. The (14)N NQR signal returned by a tablet (or tablets) from a Metakelfin batch suspected to be counterfeit was compared with that acquired from a tablet(s) from a known-to-be-genuine batch from the same named manufacturer. Metakelfin contains two active pharmaceutical ingredients, sulfalene and pyrimethamine, and NQR analysis revealed spectral differences for the sulfalene component indicative of differences in the processing history of the two batches. Furthermore, the NQR analysis provided quantitative information that the suspected counterfeit tablets contained only 43 ± 3%, as much sulfalene as the genuine Metakelfin tablets. Conversely, conventional nondestructive analysis by Fourier transform (FT)-Raman and FT-near infrared (NIR) spectroscopies only achieved differentiation between batches but no ascription. High performance liquid chromatography (HPLC)-UV analysis of the suspect tablets revealed a sulfalene content of 42 ± 2% of the labeled claim. The degree of agreement shows the promise of NQR as a means of the nondestructive identification and content-indicating first-stage analysis of counterfeit pharmaceuticals.


Assuntos
Antimaláricos/análise , Medicamentos Falsificados/análise , Espectroscopia de Ressonância Magnética/métodos , Antimaláricos/química , Medicamentos Falsificados/química , Análise de Fourier , Isótopos de Nitrogênio , Controle de Qualidade , Sensação , Análise Espectral Raman , Comprimidos
5.
Anal Chem ; 84(21): 8970-2, 2012 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-23057555

RESUMO

The performance of rectangular radio frequency (RF) coils capable of being used to detect nuclear quadrupole resonance (NQR) signals from blister packs of medicines has been compared. The performance of a fixed-pitch RF coil was compared with that from two variable-pitch coils, one based on a design in the literature and the other optimized to obtain the most homogeneous RF field over the whole volume of the coil. It has been shown from (14)N NQR measurements with two medicines, the antibiotic ampicillin (as trihydrate) and the analgesic medicine Paracetamol, that the latter design gives NQR signal intensities almost independent of the distribution of the capsules or pills within the RF coil and is therefore more suitable for quantitative analysis.


Assuntos
Acetaminofen/química , Ampicilina/química , Embalagem de Medicamentos , Espectroscopia de Ressonância Magnética/instrumentação , Ondas de Rádio , Medicamentos Falsificados/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...